新增两台联想 ThinkSystem SR860 V3 服务器到虚拟化生产集群 Add Two Lenovo ThinkSystem SR860 V3 Servers to the Virtualization Production Cluster
1、将两台 SR860 V3 服务器上架到机柜。确认电源四路接入,并做好标识与基础检查。检查服务器硬件完整性(CPU、内存、RAID 控制器、HBA、网卡)
2、SAN 连接
- 每台服务器至少双 HBA(多路径)。
- 连接到两个独立 Fabric(A/B)SAN 交换机。
3、网络连接
- 每台服务器四网口绑定(链路聚合)。
- 配置管理 VLAN。
4、SAN光交换机配置
#1、登录10.77.77.77、10.77.77.78 telnet 10.77.77.77 telnet 10.77.77.78 #2、检查 zoneset 已有成员 # show zoneset active vsan 10 zoneset name server vsan 10 zone name zone1 vsan 10 * fcid 0x880000 [interface fc1/1 swwn 20:00:00:3a:9c:ca:62:70] * fcid 0x881500 [interface fc1/2 swwn 20:00:00:3a:9c:ca:62:70] * fcid 0x880200 [interface fc1/3 swwn 20:00:00:3a:9c:ca:62:70] zone name zone2 vsan 10 * fcid 0x880000 [interface fc1/1 swwn 20:00:00:3a:9c:ca:62:70] * fcid 0x881500 [interface fc1/2 swwn 20:00:00:3a:9c:ca:62:70] * fcid 0x880600 [interface fc1/4 swwn 20:00:00:3a:9c:ca:62:70] zone name zone3 vsan 10 * fcid 0x880000 [interface fc1/1 swwn 20:00:00:3a:9c:ca:62:70] * fcid 0x881500 [interface fc1/2 swwn 20:00:00:3a:9c:ca:62:70] * fcid 0x881600 [interface fc1/5 swwn 20:00:00:3a:9c:ca:62:70] zone name zone4 vsan 10 * fcid 0x880000 [interface fc1/1 swwn 20:00:00:3a:9c:ca:62:70] * fcid 0x881500 [interface fc1/2 swwn 20:00:00:3a:9c:ca:62:70] * fcid 0x880800 [interface fc1/6 swwn 20:00:00:3a:9c:ca:62:70] zone name zone5 vsan 10 * fcid 0x880000 [interface fc1/1 swwn 20:00:00:3a:9c:ca:62:70] * fcid 0x881500 [interface fc1/2 swwn 20:00:00:3a:9c:ca:62:70] * fcid 0x880500 [interface fc1/7 swwn 20:00:00:3a:9c:ca:62:70] zone name zone6 vsan 10 * fcid 0x880000 [interface fc1/1 swwn 20:00:00:3a:9c:ca:62:70] * fcid 0x881500 [interface fc1/2 swwn 20:00:00:3a:9c:ca:62:70] * fcid 0x880400 [interface fc1/8 swwn 20:00:00:3a:9c:ca:62:70] zone name desktop01 vsan 10 * fcid 0x881300 [interface fc1/37 swwn 20:00:00:3a:9c:ca:62:70] * fcid 0x880b00 [interface fc1/38 swwn 20:00:00:3a:9c:ca:62:70] * fcid 0x880c00 [interface fc1/39 swwn 20:00:00:3a:9c:ca:62:70] zone name desktop02 vsan 10 * fcid 0x881300 [interface fc1/37 swwn 20:00:00:3a:9c:ca:62:70] * fcid 0x880b00 [interface fc1/38 swwn 20:00:00:3a:9c:ca:62:70] * fcid 0x880d00 [interface fc1/40 swwn 20:00:00:3a:9c:ca:62:70] zone name desktop03 vsan 10 * fcid 0x881300 [interface fc1/37 swwn 20:00:00:3a:9c:ca:62:70] * fcid 0x880b00 [interface fc1/38 swwn 20:00:00:3a:9c:ca:62:70] * fcid 0x880e00 [interface fc1/41 swwn 20:00:00:3a:9c:ca:62:70] zone name desktop04 vsan 10 * fcid 0x881300 [interface fc1/37 swwn 20:00:00:3a:9c:ca:62:70] * fcid 0x880b00 [interface fc1/38 swwn 20:00:00:3a:9c:ca:62:70] * fcid 0x880f00 [interface fc1/42 swwn 20:00:00:3a:9c:ca:62:70] zone name desktop05 vsan 10 * fcid 0x881300 [interface fc1/37 swwn 20:00:00:3a:9c:ca:62:70] * fcid 0x880b00 [interface fc1/38 swwn 20:00:00:3a:9c:ca:62:70] * fcid 0x881000 [interface fc1/43 swwn 20:00:00:3a:9c:ca:62:70] zone name desktop06 vsan 10 * fcid 0x881300 [interface fc1/37 swwn 20:00:00:3a:9c:ca:62:70] * fcid 0x880b00 [interface fc1/38 swwn 20:00:00:3a:9c:ca:62:70] * fcid 0x881200 [interface fc1/44 swwn 20:00:00:3a:9c:ca:62:70] #3、确认服务器是否成功连接到SAN交换机 SWFS6700UP(config)# show flogi database detail -------------------------------------------------------------------------------------------- INTERFACE VSAN FCID PORT NAME NODE NAME FLAGS -------------------------------------------------------------------------------------------- fc1/1 10 0x880000 56:c9:2b:fa:00:21:7e:20 56:c9:2b:fa:00:00:7e:20 P fc1/2 10 0x881500 56:c9:2b:fa:00:21:7e:21 56:c9:2b:fa:00:00:7e:21 P fc1/3 10 0x880200 21:00:f4:e9:d4:59:b1:04 20:00:f4:e9:d4:59:b1:04 P fc1/4 10 0x880600 21:00:f4:e9:d4:59:a6:fa 20:00:f4:e9:d4:59:a6:fa P fc1/5 10 0x881600 21:00:f4:e9:d4:59:ae:13 20:00:f4:e9:d4:59:ae:13 P fc1/6 10 0x880800 21:00:f4:e9:d4:59:a6:fe 20:00:f4:e9:d4:59:a6:fe P fc1/7 10 0x880500 21:00:34:80:0d:6e:21:98 20:00:34:80:0d:6e:21:98 P fc1/8 10 0x880400 21:00:f4:e9:d4:59:a6:e8 20:00:f4:e9:d4:59:a6:e8 P fc1/9 10 0x881700 10:00:70:b7:e4:2d:91:a6 20:00:70:b7:e4:2d:91:a6 P fc1/10 10 0x881800 10:00:70:b7:e4:2d:91:6a 20:00:70:b7:e4:2d:91:6a P fc1/37 10 0x881300 56:c9:2b:fa:00:21:89:90 56:c9:2b:fa:00:00:89:90 P fc1/38 10 0x880b00 56:c9:2b:fa:00:22:89:91 56:c9:2b:fa:00:00:89:91 P fc1/39 10 0x880c00 10:00:00:10:9b:c6:9f:ab 20:00:00:10:9b:c6:9f:ab P fc1/40 10 0x880d00 10:00:00:10:9b:c6:9f:cf 20:00:00:10:9b:c6:9f:cf P fc1/41 10 0x880e00 10:00:00:10:9b:c6:9b:45 20:00:00:10:9b:c6:9b:45 P fc1/42 10 0x880f00 10:00:00:10:9b:c6:b1:3c 20:00:00:10:9b:c6:b1:3c P fc1/43 10 0x881000 10:00:00:10:9b:c6:9d:f9 20:00:00:10:9b:c6:9d:f9 P fc1/44 10 0x881200 10:00:00:10:9b:c6:b4:2d 20:00:00:10:9b:c6:b4:2d P Total number of flogi = 18. FLAGS: A area FCID allocation L loop device V FDISC D the wwn matches the default OUI list O the wwn matches the configured OUI list P allocation was done based on the persistency table M indicates a VMID capable FCID #4、新增zone,添加新服务器接口 #zone name zone7 vsan 10 member interface fc1/1 member interface fc1/2 member interface fc1/9 #zone name zone8 vsan 10 member interface fc1/1 member interface fc1/2 member interface fc1/10 zoneset name server vsan 10 member zone7 member zone8 #5、激活 zoneset zoneset activate name server vsan 10 show zoneset active vsan 10 show flogi database vsan 10 #6、保存配置 copy running-config startup-config #7、修改 zone 成员(如有误)(fc1/7 → fc1/9) 进入 zone 配置模式 conf t zone name zone7 vsan 10 no member interface fc1/7 member interface fc1/9

5、网络交换机配置
# interface Eth-Trunk7 description LenovoUP port link-type trunk port trunk allow-pass vlan 2 to 4094 mode lacp-dynamic # interface Eth-Trunk8 port link-type trunk port trunk allow-pass vlan 2 to 4094 mode lacp-dynamic # # interface 10GE1/0/25 eth-trunk 7 device transceiver 10GBASE-FIBER # interface 10GE1/0/26 eth-trunk 7 device transceiver 10GBASE-FIBER # interface 10GE1/0/27 eth-trunk 7 device transceiver 10GBASE-FIBER # interface 10GE1/0/28 eth-trunk 7 device transceiver 10GBASE-FIBER # interface 10GE1/0/29 eth-trunk 8 device transceiver 10GBASE-FIBER # interface 10GE1/0/30 eth-trunk 8 device transceiver 10GBASE-FIBER # interface 10GE1/0/31 eth-trunk 8 device transceiver 10GBASE-FIBER # interface 10GE1/0/32 eth-trunk 8 device transceiver 10GBASE-FIBER #
6、存储添加和卷映射主机

6、服务器安装ESXi7操作系统

7、更新ESXi补丁
# esxcli software sources profile list -d /vmfs/volumes/60071865-c14e10d6-bc6f-b4055d4dc1b4/ISO/VMware-ESXi-7.0U3w-24784741-depot.zip Name Vendor Acceptance Level Creation Time Modification Time ----------------------------- ------------ ---------------- ------------------- ----------------- ESXi-7.0U3w-24784741-standard VMware, Inc. PartnerSupported 2025-07-15T00:00:00 2025-07-15T00:00:00 ESXi-7.0U3w-24784741-no-tools VMware, Inc. PartnerSupported 2025-07-15T00:00:00 2025-06-09T07:05:28 # esxcli software profile update -p ESXi-7.0U3w-24784741-standard -d /vmfs/volumes/60071865-c14e10d6-bc6f-b4055d4dc1b4/ISO/VMware-ESXi-7.0U3w-24784741-depot.zip
8、配置 vSwitch0
负载均衡 修改为 基于 IP 哈希的路由
9、创建 vMotion 网络(vMotion_Network)用于虚拟机迁移。
10、FS6700和博科620SAN交换机配置区别
| 功能 | Cisco(思科 MDS) | Brocade(博科) | 核心区别 / 注意事项 |
|---|---|---|---|
| 进入配置模式 | conf t |
configure(很少用在zoning) |
Cisco 强依赖配置模式;Brocade zoning 多为直接命令 |
| 定义逻辑域 | vsan database vsan 10 |
❌(无 VSAN,单 Fabric) | 最大区别:Cisco 支持 VSAN 多租户隔离,Brocade 不支持** |
| 创建别名 | fcalias name host1 vsan 10 member pwwn xx |
alicreate "host1","pwwn" |
本质一样(alias),但 Cisco 必须绑定 VSAN |
| 创建zone(两个成员) | zone name zone1 vsan 10 member fcalias host1 member fcalias storage1 |
zonecreate "zone1","host1;storage1" |
Cisco 多行配置;Brocade 一行完成 |
| 添加成员到zone | member fcalias host2 |
zoneadd "zone1","host2" |
Brocade 支持直接追加;Cisco 在 zone 下操作 |
| 创建zone集合 | zoneset name zs1 vsan 10 member zone1 |
cfgcreate "cfg1","zone1" |
zoneset = cfg(最关键映射) |
| 添加zone到集合 | member zone2 |
cfgadd "cfg1","zone2" |
Cisco 是上下文命令;Brocade 是独立命令 |
| 激活配置 | zoneset activate name zs1 vsan 10 |
cfgenable "cfg1" |
Cisco 按 VSAN 激活;Brocade 全局激活 |
| 保存配置 | copy running-config startup-config |
cfgsave |
Brocade 不保存会丢;Cisco 也一样但机制不同 |
| 查看激活配置 | show zoneset active vsan 10 |
cfgactvshow |
Cisco 需要指定 VSAN |
| 查看全部配置 | show zone |
cfgshow |